Usefulness of Frequency Domain Optical Coherence Tomography Compared with Intravascular Ultrasound as a Guidance for Percutaneous Coronary Intervention.

Metadata Downloads
Affiliated Author(s)
김인철윤혁준조윤경박형섭김형섭남창욱한성욱김윤년김권배허승호
Alternative Author(s)
Kim, In CheolYoon, Hyuck JunCho, Yun KyeongPark, Hyoung SeobKim, Hyung SeopNam, Chang WookHan, Seong WookKim, Yoon NyunKim, Kwon BaeHur, Seung Ho
Journal Title
Journal of Interventional Cardiology
ISSN
1540-8183
Issued Date
2016
Abstract
Objectives: To compare outcomes and rates of optimal stent placement between optical coherence tomography
(OCT) and intravascular ultrasound (IVUS) guided percutaneous coronary intervention (PCI).
Background: Unlike IVUS-guided PCI, rates of clinical outcomes and optimal stent placement have not been well
characterized for OCT-guided PCI.
Methods: The study enrolled 290 patients who underwent implantation of a second generation drug eluting stent
under OCT (122 patients) or IVUS (168 patients) guidance. The two groups were compared after adjusting for
baseline differences using 1:1 propensity score matching (PSM) (114 patients in each group). Optimal stent
placement was defined as achieving an adequate lumen (optimal minimum stent area [MSA > 4.85 mm
2
for OCT,
>5mm
2
for IVUS] or a final MSA  90% of the distal reference lumen area, without edge dissection, incomplete
stent apposition, or tissue prolapse), or otherwise performing additional interventions to address suboptimal post-
stenting OCT or IVUS findings. The primary endpoint was one-year cumulative incidence of major adverse cardiac
events (MACE; cardiac death, myocardial infarction and target lesion revascularization). Definite or probable
stent thrombosis (ST) rates were evaluated.
Results: In adjusted comparisons between OCT and IVUS groups, there was no significant difference in rates of
MACE (3.5% vs. 3.5%, P ¼ 1.000) and ST (0% vs. 0.9%, P ¼ 1.000) at 1 year, optimal stent placement (89.5% vs.
92.1%, P ¼ 0.492), and further intervention (7.9% vs.13.2%, P ¼ 0.234), despite OCT significantly more frequently
detecting tissue prolapse (97.4% vs. 47.4%, P < 0.001), and numerically more edge dissection (10.5% vs. 4.4%,
P ¼ 0.078) or incomplete stent apposition (48.2% vs. 36.8%, P ¼ 0.082).
Conclusions: OCT guidance showed comparable results to IVUS in mid-term clinical outcomes, suggesting that
OCT can be an alternative tool for stent placement optimization
Department
Dept. of Internal Medicine (내과학)
Publisher
School of Medicine
Citation
In-Cheol Kim et al. (2016). Usefulness of Frequency Domain Optical Coherence Tomography Compared with Intravascular Ultrasound as a Guidance for Percutaneous Coronary Intervention. Journal of Interventional Cardiology, 29(2), 216–224. doi: 10.1111/joic.12276
Type
Article
ISSN
1540-8183
DOI
10.1111/joic.12276
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/33381
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Internal Medicine (내과학)
공개 및 라이선스
  • 공개 구분공개
  • 엠바고Forever
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.