계명대학교 의학도서관 Repository

Effectiveness of Implantable Cardioverter-Defibrillator Therapy for Heart Failure Patients according to Ischemic or Non-Ischemic Etiology in Korea

Metadata Downloads
Affiliated Author(s)
한성욱김윤년박형섭
Alternative Author(s)
Han, Seong WookKim, Yoon NyunPark, Hyoung Seob
Journal Title
Korean Circulation Journal
ISSN
1738-5520
Issued Date
2017
Keyword
Heart failureImplantable cardioverter-defibrillatorLeft ventricular dysfunctionMortality
Abstract
BACKGROUND AND OBJECTIVES:

This study was performed to describe clinical characteristics of patients with left ventriculars (LV) dysfunction and implantable cardioverter-defibrillator (ICD), and to evaluate the effect of ICD therapy on survival in Yeongnam province of Korea.

SUBJECTS AND METHODS:

From a community-based device registry (9 centers, Yeongnam province, from November 1999 to September 2012), 146 patients with LV dysfunction and an ICD implanted for primary or secondary prophylaxis, were analyzed. The patients were divided into two groups, based on the etiology (73 with ischemic cardiomyopathy and 73 with non-ischemic cardiomyopathy), and indication for the device implantation (36 for primary prevention and 110 for secondary prevention). The cumulative first shock rate, all cause death, and type and mode of death, were determined according to the etiology and indication.

RESULTS:

Over a mean follow-up of 3.5 years, the overall ICD shock rate was about 39.0%. ICD shock therapy was significantly more frequent in the secondary prevention group (46.4% vs. 16.7%, p=0.002). The cumulative probability of a first appropriate shock was higher in the secondary prevention group (p=0.015). There was no significant difference in the all-cause death, cardiac death, and mode of death between the groups according to the etiology and indication.

CONCLUSION:

Studies from this multicenter regional registry data shows that in both ischemic and non-ischemic cardiomyopathy patients, the ICD shock therapy rate was higher in the secondary prevention group than primary prevention group.
Department
Dept. of Internal Medicine (내과학)
Publisher
School of Medicine (의과대학)
Citation
Kyu-Hwan Park et al. (2017). Effectiveness of Implantable Cardioverter-Defibrillator Therapy for Heart Failure Patients according to Ischemic or Non-Ischemic Etiology in Korea. Korean Circulation Journal, 47(1), 72–81. doi: 10.4070/kcj.2016.0242
Type
Article
ISSN
1738-5520
DOI
10.4070/kcj.2016.0242
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/41212
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Internal Medicine (내과학)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.