계명대학교 의학도서관 Repository

Computer-aided automatic measurement of leg length on full leg radiographs

Metadata Downloads
Affiliated Author(s)
이무숙
Alternative Author(s)
Lee, Mu Sook
Journal Title
Skeletal Radiol
ISSN
1432-2161
Issued Date
2022
Keyword
Deep learningFull leg radiographyLeg length measurementRetrospective studies
Abstract
Objectives:
To develop and evaluate a deep learning (DL)–based system for measuring leg length on full leg radiographs of diverse patients, including those with orthopedic hardware implanted for surgical treatment.

Methods:
This study retrospectively assessed 2767 X-ray scanograms of 2767 patients who did or did not have orthopedic hardware implanted between January 2016 and December 2019. A cascaded DL model was developed to localize the relevant landmarks on the pelvis, knees, and ankles required for measuring leg length. Statistical analysis was performed using the correlation coefficient analysis and Bland–Altman plots to assess the agreement between the reference standard and DL-calculated lengths.

Results:
Testing data comprised 400 radiographs from 400 patients. Of these radiographs, 100 were from patients with orthopedic hardware implanted in their pelvis, knees, or ankles. For all testing data, leg lengths derived from the DL-based measurement system, with or without internal fixation devices, showed excellent agreement with the reference standard (femoral length, r = 0.99 (P < .001); root mean square error (RMSE) = 0.17 cm; mean difference, − 0.01 ± 0.17 cm; 95% limit of agreement (LoA), − 0.35 to 0.34; tibial length, r = 0.99 (P < .001); RMSE = 0.17 cm; mean difference, − 0.02 ± 0.17 cm, 95% LoA, − 0.34 to 0.31; and full leg length, r = 1.0 (P < .001); RMSE = 0.19 cm; mean difference, 0.05 ± 0.18 cm; 95% LoA, − 0.31 to 0.40). The mean time for leg length measurement for each patient using the DL-based system was 8.68 ± 0.18 s.

Conclusion:
The DL-based leg length measurement system could provide similar performance to radiologists in terms of accuracy and reliability for a diverse group of patients.
Department
Dept. of Radiology (영상의학)
Publisher
School of Medicine (의과대학)
Citation
Chan Su Lee et al. (2022). Computer-aided automatic measurement of leg length on full leg radiographs. Skeletal Radiol, 51(5), 1007–1016. doi: 10.1007/s00256-021-03928-z
Type
Article
ISSN
1432-2161
DOI
10.1007/s00256-021-03928-z
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/44067
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Radiology (영상의학)
공개 및 라이선스
  • 공개 구분공개
  • 엠바고Forever
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.