계명대학교 의학도서관 Repository

초음파 생체계측에 의한 전시안의 안축장에 관한 고찰

Metadata Downloads
Affiliated Author(s)
김기산조윤애
Alternative Author(s)
Kim, Ki SanCho, Yoon Ae
Journal Title
Keimyung Medical Journal
Issued Date
1983
Abstract
We measured the axial length of 170 normal emmetropic eyes using the A-mode of the Ocuscan-400 from Feb. 1, 1982 to August 31. 1982. The results were as follows; 1. The range of the axial length of the eyeball was from 21.73mm to 25.47mm. 2. The mean axial length was 23.62mm, that of males was 23.87mm and 23.22mm in femaies. 3. The eyes with axial length from 23.00 to 24.50mm were found in 103 eyes of 170 eyes (60.6%) and axial lengths below 22.00mm were found in 5 of 170 eyes (2.9%) and above 25.00mm in 6 of 170 eyes (35%).
Alternative Title
The Axial Length of Normal Emmetropic Eyes by Ultrasonic Biometry
Department
Dept. of Ophthalmology (안과학)
Publisher
Keimyung University School of Medicine
Citation
이내호 et al. (1983). 초음파 생체계측에 의한 전시안의 안축장에 관한 고찰. Keimyung Medical Journal, 2(1), 79–83.