Evaluation of variability in target volume delineation for newly diagnosed glioblastoma: a multi-institutional study from the Korean Radiation Oncology Group
- Author(s)
- Chan Woo Wee; Wonmo Sung; Hyun-Cheol Kang; Kwan Ho Cho; Tae Jin Han; Bae-Kwon Jeong; Jae-Uk Jeong; Haeyoung Kim; In Ah Kim; Jin Hee Kim; Sung Hwan Kim; Suzy Kim; Dong Soo Lee; Me Yeon Lee; Do Hoon Lim; Hye Li Park; Chang-Ok Suh; Sang Min Yoon; Il Han Kim
- Keimyung Author(s)
- Kim, Jin Hee
- Department
- Dept. of Radiation Oncology (방사선종양학)
- Journal Title
- Radiation oncology
- Issued Date
- 2015
- Volume
- 10
- Issue
- 137
- Keyword
- Glioblastoma; Target volume; Peritumoral edema; STAPLE; Margin
- Abstract
- Background: This study aimed for a collaborative evaluation of variability in the target volumes for glioblastoma,
determined and contoured by different radiotherapy (RT) facilities in Korea.
Methods: Fifteen panels of radiation oncologists from independent institutions contoured the gross target volumes
(GTVs) and clinical target volumes (CTVs) for 3-dimensional conformal RT or intensity-modulated RT on each simulation
CT images, after scrutinizing the enhanced T1-weighted and T2-weighted-fluid-attenuated inversion recovery MR images
of 9 different cases of glioblastoma. Degrees of contouring agreement were analyzed by the kappa statistics. Using the
algorithm of simultaneous truth and performance level estimation (STAPLE), GTVSTAPLE and CTVSTAPLE contours
were derived.
Results: Contour agreement was moderate (mean kappa 0.58) among the GTVs and was substantial (mean kappa
0.65) among the CTVs. However, each panels’ GTVs and modification of CTVs regarding anatomical structures
varied. Three-fourth of contoured panels’ CTVs encompassed the peritumoral areas of T2-high signal intensity
(T2-HSI). Nine of nine GTVSTAPLE encompased the surgical cavity and the T1-enhanced lesions. Eight of nine
CTVSTAPLE encompassed the peritumoral T2-HSI area. The median MARGIN90 and the median MARGIN95 were
1.4 cm and 1.5 cm, respectively.
Conclusions: Moderate to substantial agreement existed in target volumes for 3-dimensional or intensity-modulated
RT determined by radiation oncologists in Korea. According to the estimated consensus contours, the initial CTV
encompassed the GTV with margin less than 2.0 cm and the whole peritumoral areas of T2-HSI. The findings of our
study propose the need for further studies and modified guidelines.
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.