계명대학교 의학도서관 Repository

Evaluation of variability in target volume delineation for newly diagnosed glioblastoma: a multi-institutional study from the Korean Radiation Oncology Group

Metadata Downloads
Author(s)
Chan Woo WeeWonmo SungHyun-Cheol KangKwan Ho ChoTae Jin HanBae-Kwon JeongJae-Uk JeongHaeyoung KimIn Ah KimJin Hee KimSung Hwan KimSuzy KimDong Soo LeeMe Yeon LeeDo Hoon LimHye Li ParkChang-Ok SuhSang Min YoonIl Han Kim
Keimyung Author(s)
Kim, Jin Hee
Department
Dept. of Radiation Oncology (방사선종양학)
Journal Title
Radiation oncology
Issued Date
2015
Volume
10
Issue
137
Keyword
GlioblastomaTarget volumePeritumoral edemaSTAPLEMargin
Abstract
Background: This study aimed for a collaborative evaluation of variability in the target volumes for glioblastoma,
determined and contoured by different radiotherapy (RT) facilities in Korea.
Methods: Fifteen panels of radiation oncologists from independent institutions contoured the gross target volumes
(GTVs) and clinical target volumes (CTVs) for 3-dimensional conformal RT or intensity-modulated RT on each simulation
CT images, after scrutinizing the enhanced T1-weighted and T2-weighted-fluid-attenuated inversion recovery MR images
of 9 different cases of glioblastoma. Degrees of contouring agreement were analyzed by the kappa statistics. Using the
algorithm of simultaneous truth and performance level estimation (STAPLE), GTVSTAPLE and CTVSTAPLE contours
were derived.
Results: Contour agreement was moderate (mean kappa 0.58) among the GTVs and was substantial (mean kappa
0.65) among the CTVs. However, each panels’ GTVs and modification of CTVs regarding anatomical structures
varied. Three-fourth of contoured panels’ CTVs encompassed the peritumoral areas of T2-high signal intensity
(T2-HSI). Nine of nine GTVSTAPLE encompased the surgical cavity and the T1-enhanced lesions. Eight of nine
CTVSTAPLE encompassed the peritumoral T2-HSI area. The median MARGIN90 and the median MARGIN95 were
1.4 cm and 1.5 cm, respectively.
Conclusions: Moderate to substantial agreement existed in target volumes for 3-dimensional or intensity-modulated
RT determined by radiation oncologists in Korea. According to the estimated consensus contours, the initial CTV
encompassed the GTV with margin less than 2.0 cm and the whole peritumoral areas of T2-HSI. The findings of our
study propose the need for further studies and modified guidelines.
Keimyung Author(s)(Kor)
김진희
Publisher
School of Medicine
Citation
Chan Woo Wee et al. (2015). Evaluation of variability in target volume delineation for newly diagnosed glioblastoma: a multi-institutional study from the Korean Radiation Oncology Group. Radiation oncology, 10(137), 1–9. doi: 10.1186/s13014-015-0439-z
Type
Article
ISSN
1748-717X
DOI
10.1186/s13014-015-0439-z
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/32968
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.