계명대학교 의학도서관 Repository

Is Iterative Reconstruction an Improvement Over Filtered Back Projection in Processing Gated Myocardial Perfusion SPECT?

Metadata Downloads
Author(s)
Kyoung Sook WonE. Edmund KimMartha MarSalman GoharWilliam ErwinWei WeiIsis Gayed
Keimyung Author(s)
Won, Kyoung Sook
Department
Dept. of Nuclear Medicine (핵의학)
Journal Title
Open Medical Imaging Journal
Issued Date
2008
Volume
2
Issue
1
Keyword
Myocardial perfusion scintigraphySPECTIterative reconstructionFiltered back-projectionSPECT reconstruction algorithms
Abstract
The impact of iterative reconstruction (IR) on myocardial perfusion imaging (MPI) interpretation and func-
tional results is under investigated. We evaluated the effect of IR on the interpretation and functional results of MPI com-
pared with filtered back-projection (FBP). Material and Methods: Sixty patients with previously acquired MPI were ran-
domly selected. Studies were processed using FBP and 2D ordered-subsets expectation-maximization (OSEM). Two phy-
sicians interpreted the images after IR and FBP processing. Results were confirmed by coronary angiography and/or clini-
cal course. Left ventricular ejection fraction (LVEF), end-diastolic volume (EDV) and end-systolic volume (ESV) were
calculated with IR and FBP. Results: The sensitivity, specificity, positive and negative predictive values and accuracy of
physician 1 were 95%, 87%, 80%, 97%, and 90% with FBP and 100%, 80%, 72%, 100%, and 87% with IR. For physician
2, they were 95%, 95%, 91%, 97%, and 95% with FBP and 81%, 95%, 90%, 90%, and 90% with IR. There were no statis-
tically significant differences between physicians’ interpretations (P=0.71 for FBP and 0.09 for IR). There was good cor-
relation between IR and FBP calculated LVEF (r=0.98), EDV (r=0.99), and ESV (r=0.99) but significant difference per
patient (P=0.02, 0.03 and 0.02, respectively). Conclusion: There is no statistically significant difference in interpretation
of MPI with IR versus FBP but there were statistically significant differences in functional results.
Keywords: Myocardial perfusion scintigraphy, SPECT, Iterative reconstruction, Filtered back-projection, SPECT reconstruc-
tion algorithms.
Keimyung Author(s)(Kor)
원경숙
Publisher
School of Medicine
Citation
Kyoung Sook Won et al. (2008). Is Iterative Reconstruction an Improvement Over Filtered Back Projection in Processing Gated Myocardial Perfusion SPECT? Open Medical Imaging Journal, 2(1), 17–23. doi: 10.2174/1874347100802010017
Type
Article
ISSN
1874-3471
DOI
10.2174/1874347100802010017
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/34640
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Nuclear Medicine (핵의학)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.