계명대학교 의학도서관 Repository

Temporal Evolution of Strut Light Intensity After Implantation of Bioresorbable Polymeric Intracoronary Scaffolds in the ABSORB Cohort B Trial – An Application of a New Quantitative Method Based on Optical Coherence Tomography –

Metadata Downloads
Author(s)
Shimpei NakataniYoshinobu OnumaYuki IshibashiJeroen EggermontYao-Jun ZhangCarlos M. CamposYun Kyeong ChoShengnan LiuJouke DijkstraJohan H.C. ReiberLaura PerkinsAlexander SheehySusan VeldhofRichard RapozaGerrit-Anne van EsHector M. Garcia-GarciaRobert-Jan van GeunsPatrick W. Serruys
Keimyung Author(s)
Cho, Yun Kyeong
Department
Dept. of Internal Medicine (내과학)
Journal Title
Circulation Journal
Issued Date
2014
Volume
78
Issue
8
Abstract
Background:Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial.Methods and Results:In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months).Conclusions:Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.
Keimyung Author(s)(Kor)
조윤경
Publisher
School of Medicine
Citation
Shimpei Nakatani et al. (2014). Temporal Evolution of Strut Light Intensity After Implantation of Bioresorbable Polymeric Intracoronary Scaffolds in the ABSORB Cohort B Trial
– An Application of a New Quantitative Method Based on Optical Coherence Tomography –. Circulation Journal, 78(8), 1873–1881. doi: 10.1253/circj.CJ-14-0143
Type
Article
ISSN
1346-9843
DOI
10.1253/circj.CJ-14-0143
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/35415
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Internal Medicine (내과학)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.