Prospective Randomized Study to Assess the Efficacy of Site and Rate of Atrial Pacing on Long-Term Progression of Atrial Fibrillation in Sick Sinus Syndrome Septal Pacing for Atrial Fibrillation Suppression Evaluation (SAFE) Study
- Author(s)
- Chu-Pak Lau; Ngarmukos Tachapong; Chun-Chieh Wang; Jing-feng Wang; Haruhiko Abe; Chi-Woon Kong; Reginald Liew; Dong-Gu Shin; Luigi Padeletti; You-Ho Kim; Razali Omar; Kreingkrai Jirarojanakorn; Yoon-Nyun Kim; Mien-Cheng Chen; Charn Sriratanasathavorn; Muhammad Munawar; Ruth Kam; Jan-Yow Chen; Yong-Keun Cho; Yi-Gang Li; Shu-Lin Wu; Christophe Bailleul; Hung-Fat Tse
- Keimyung Author(s)
- Kim, Yoon Nyun
- Department
- Dept. of Internal Medicine (내과학)
- Journal Title
- Circulation
- Issued Date
- 2013
- Volume
- 128
- Issue
- 7
- Abstract
- Background—Atrial-based pacing is associated with lower risk of atrial fibrillation (AF) in sick sinus syndrome compared with ventricular pacing; nevertheless, the impact of site and rate of atrial pacing on progression of AF remains unclear. We evaluated whether long-term atrial pacing at the right atrial (RA) appendage versus the low RA septum with (ON) or without (OFF) a continuous atrial overdrive pacing algorithm can prevent the development of persistent AF.
Methods and Results—We randomized 385 patients with paroxysmal AF and sick sinus syndrome in whom a pacemaker was indicated to pacing at RA appendage ON (n=98), RA appendage OFF (n=99), RA septum ON (n=92), or RA septum OFF (n=96). The primary outcome was the occurrence of persistent AF (AF documented at least 7 days apart or need for cardioversion). Demographic data were homogeneous across both pacing site (RA appendage/RA septum) and atrial overdrive pacing (ON/OFF). After a mean follow-up of 3.1 years, persistent AF occurred in 99 patients (25.8%; annual rate of persistent AF, 8.3%). Alternative site pacing at the RA septum versus conventional RA appendage (hazard ratio=1.18; 95% confidence interval, 0.79–1.75; P=0.65) or continuous atrial overdrive pacing ON versus OFF (hazard ratio=1.17; 95% confidence interval, 0.79–1.74; P=0.69) did not prevent the development of persistent AF.
Conclusions—In patients with paroxysmal AF and sick sinus syndrome requiring pacemaker implantation, an alternative atrial pacing site at the RA septum or continuous atrial overdrive pacing did not prevent the development of persistent AF.
Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT00419640.
Key Words: atrial fibrillation
cardiac pacing, artificial
sick sinus syndrome
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.