입력가진 조건에 따른 선형 시스템의 피로손상도 비교 평가
- Author(s)
- 허윤석; 김찬중
- Keimyung Author(s)
- Heo, Yun Seok
- Department
- Dept. of Biomedical Engineering (의용공학과)
- Journal Title
- 한국소음진동공학회 논문집
- Issued Date
- 2014
- Volume
- 24
- Issue
- 6
- Keyword
- Sine on Random; Fatigue Damage; Uniaxial Excitation; Input Condition; Linear Elastic System; sineonrandom; fatiguedamage; uniaxialexcitation; inputcondition; linearelasticsystem
- Abstract
- Vibration testing is conducted for evaluate the fatigue resistance of responsible system over excitation situations and two kinds of vibration profiles, harmonic or random, are widely used in engineering fields. Harmonic excitation profile is adequate for the rotating machinery that is primarily exposed to the orderly excited force subjected for a rotating speed; Random profile is suitable for the non-stationary vibration input, that is a ground excitation for example. Recently, the sine on random(SOR) testing method was sometimes considered to represent the real excitation conditions since the measured response signals of a target system, expecially for moving mobility, shows usually a mixture of them. So, it is important to understand the accumulated fatigue damage over different excitation patterns, harmonic and/or random, to determine the efficient vibration profile of a target system. A uniaxial vibration testing with a notched simple beam was introduced to evaluate the fatigue damage for different excitation profiles and the best choice of vibration profile was concluded from those comparison of calculated fatigue damages
- 공개 및 라이선스
-
- 파일 목록
-