Abstract
The operative treatment of displaced acetabuilar fracture has become the preferred method than conservative treatment. Displaced acetabular fracture occurs primarily in young adult involved in high energy trauma and it can lead to some degree of permanent disability. The aim of treatment' must be the restoration of hip function which require accurate anatomical reduction and firm fixation followed by early exercise. The complicated anatomy of the region, and unsatisfactory fixation to cancellous bone, and unnecessary wide dissection of the soft tissue for plate and screw fixation contribute to clinical end results of varying success. The wire loop which was previously reported by our department as a successful method of fixation has now been developed to cable fixation that can be easily adjusted to the irregutar surface of acetabulum and get more firm fixation. A clinical anaiysis was performed on 14 patients with displaced unstable acetabular fracture who had been fixed by cable and followed for minimum 1 year period at our department from June 1993 to June 1994. The results were follows; l. According to Letorunel's classification, there were most common (9 cases:64.4%) in both column fracture, 3 cases(21.4%) in T shaped fracture, 1 case(7.l%) in transverse fracture. and I case(7.1%) in transverse and posterior wall fracture.2. The satisfactory result was achieved in 12 cases(85.7%) on clinical grade and l2 cases(85,7%) on radiographic grade according to Epstein criteria. 3. The complication were developed in 3 cases(21.4%) out of 14 cases, such as posttraumatic arthritis in 2 cases and tansient sciatic nerve palsy in 1 case. 4. Cable fixation provides a more secure and easy fixation and require a narrower exposure than a plate fixation.
Alternative Title
Cable Fixation Method for Displaced Acetabular Fracture
Keimyung Author(s)(Kor)
강창수
민병우
송광순
강철형
Publisher
School of Medicine
Citation
강창수 et al. (1996). 케이블 고정법을 이용한 전위성 비구 골절의 치료. 대한골절학회지, 9(3), 574–582. doi:  10.12671/jksf.1996.9.3.574
Type
Article
ISSN
1225-1682
DOI
 10.12671/jksf.1996.9.3.574
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/37648
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.