계명대학교 의학도서관 Repository

유착방지제 사용 후 발생한 이물반응 1예

Metadata Downloads
Author(s)
김지룡정주형여창기
Keimyung Author(s)
Yeo, Chang Ki
Department
Dept. of Otorhinolaryngology (이비인후과학)
Journal Title
대한이비인후과학회지 두경부외과학
Issued Date
2018
Volume
61
Issue
5
Keyword
AdhesionPolylactic acidSide effectsSurgiWrap
Abstract
Postsurgical adhesion formation is a significant clinical problem within every surgical specialty. Currently, adhesion barriers are used in many surgical interventions and while theyhave become a subject of an increasing interest for their effectiveness, there has not been anyreports on the adverse effects of these anti-adhesion agents. Three different types of antiadhesiveagents (SurgiWrapⓇ, Guardix-SolⓇ, InterceedⓇ) have been noted as effective in adhesionprevention. We report, with a review of literature, on a patient who had a foreign body reactionthat caused a side effect of anti-adhesion SurgiWrapⓇ after thyroid surgery.
Alternative Title
Foreign Body Reactions after Using SurgiWrapⓇ (Polylactide Acid Bioresorbable Sheet)
Keimyung Author(s)(Kor)
여창기
Publisher
School of Medicine (의과대학)
Citation
김지룡 et al. (2018). 유착방지제 사용 후 발생한 이물반응 1예. 대한이비인후과학회지 두경부외과학, 61(5), 267–269. doi: 10.3342/kjorl-hns.2016.17412
Type
Article
ISSN
2092-5859
DOI
10.3342/kjorl-hns.2016.17412
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/41611
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Otorhinolaryngology (이비인후과학)