유착방지제 사용 후 발생한 이물반응 1예
- Author(s)
- 김지룡; 정주형; 여창기
- Keimyung Author(s)
- Yeo, Chang Ki
- Department
- Dept. of Otorhinolaryngology (이비인후과학)
- Journal Title
- 대한이비인후과학회지 두경부외과학
- Issued Date
- 2018
- Volume
- 61
- Issue
- 5
- Keyword
- Adhesion; Polylactic acid; Side effects; SurgiWrap
- Abstract
- Postsurgical adhesion formation is a significant clinical problem within every surgical specialty. Currently, adhesion barriers are used in many surgical interventions and while theyhave become a subject of an increasing interest for their effectiveness, there has not been anyreports on the adverse effects of these anti-adhesion agents. Three different types of antiadhesiveagents (SurgiWrapⓇ, Guardix-SolⓇ, InterceedⓇ) have been noted as effective in adhesionprevention. We report, with a review of literature, on a patient who had a foreign body reactionthat caused a side effect of anti-adhesion SurgiWrapⓇ after thyroid surgery.