계명대학교 의학도서관 Repository

Dummy Run of Quality Assurance Program before Prospective Study of Hippocampus-Sparing Whole-Brain Radiotherapy and Simultaneous Integrated Boost for Multiple Brain Metastases from Non-small Cell Lung Cancer: Korean Radiation Oncology Group (KROG) 17-06 Study

Metadata Downloads
Author(s)
Eunah ChungJae Myoung NohKyu Chan LeeJin Hee KimWeon Kuu ChungYang-Gun SuhJung Ae LeeKi Ho SeolHong Gyun WuYeon Sil KimO Kyu NohJae Won ParkDong Soo LeeJihae LeeYoung Suk KimWoo-Yoon ParkMin Kyu KangSunmi JoYong Chan Ahn
Keimyung Author(s)
Kim, Jin Hee
Department
Dept. of Radiation Oncology (방사선종양학)
Journal Title
Cancer Research and Treatment
Issued Date
2019
Volume
51
Issue
3
Keyword
Hippocampus-sparing whole brain radiotherapyDummy runMulti-institutional studyQA programNon-small cell lung cancer
Abstract
Purpose
Lung Cancer Subcommittee of Korean Radiation Oncology Group (KROG) has recently launched a prospective clinical trial (KROG 17-06) of hippocampus-sparing whole brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in treating multiple brain metastases from non-small cell lung cancer. In order to improve trial quality, dummy run studies among the participating institutions were designed. This work reported the results of two-step dummy run procedures of the KROG 17-06 study.

Materials and Methods
Two steps tested hippocampus contouring variability and radiation therapy planning compliance. In the first step, the variation of the hippocampus delineation was investigated for two representative cases using the Dice similarity coefficients. In the second step, the participating institutions were requested to generate a HS-WBRT with SIB treatment plan for another representative case. The compliance of the treatment plans to the planning protocol was evaluated.

Results
In the first step, the median Dice similarity coefficients of the hippocampus contours for two other dummy run cases changed from 0.669 (range, 0.073 to 0.712) to 0.690 (range, 0.522 to 0.750) and from 0.291 (range, 0.219 to 0.522) to 0.412 (range, 0.264 to 0.598) after providing the hippocampus contouring feedback. In the second step, with providing additional plan priority and extended dose constraints to the target volumes and normal structures, we observed the improved compliance of the treatment plans to the planning protocol.

Conclusion
The dummy run studies demonstrated the notable inter-institutional variability in delineating the hippocampus and treatment plan generation, which could be decreased through feedback from the trial center.
Keimyung Author(s)(Kor)
김진희
Publisher
School of Medicine (의과대학)
Citation
Eunah Chung et al. (2019). Dummy Run of Quality Assurance Program before Prospective Study of Hippocampus-Sparing Whole-Brain Radiotherapy and Simultaneous Integrated Boost for Multiple Brain Metastases from Non-small Cell Lung Cancer: Korean Radiation Oncology Group (KROG) 17-06 Study. Cancer Research and Treatment, 51(3), 1001–1010. doi: 10.4143/crt.2018.415
Type
Article
ISSN
2005-9256
Source
https://www.e-crt.org/journal/view.php?doi=10.4143/crt.2018.415
DOI
10.4143/crt.2018.415
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/41805
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.