Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study
- Author(s)
- Henrik Gensicke; James W Evans; Fahad S Al Ajlan; Dar Dowlatshahi; Mohamed Najm; Ana L Calleja; Josep Puig; Sung-lI Sohn; Seong H Ahn; Alexandre Y Poppe; Robert Mikulik; Negar Asdaghi; Thalia S Field; Albert Jin; Talip Asil; Jean-Martin Boulanger; Michael D Hill; Mayank Goyal; Andrew M Demchuk; Bijoy K Menon
- Keimyung Author(s)
- Sohn, Sung Il
- Department
- Dept. of Neurology (신경과학)
- Journal Title
- Neuroradiology
- Issued Date
- 2020
- Volume
- 62
- Issue
- 3
- Keyword
- Acute ischemic stroke; CTA; NCCT; Recanalization therapies; Thrombus permeability
- Abstract
- Purpose:
To compare the association of different measures of intracranial thrombus permeability on non-contrast computerized tomography (NCCT) and computed tomography angiography (CTA) with recanalization with or without intravenous alteplase.
Methods:
Patients with anterior circulation occlusion from the INTERRSeCT study were included. Thrombus permeability was measured on non-contrast CT and CTA using the following methods: [1] automated method, mean attenuation increase on co-registered thin (< 2.5 mm) CTA/NCCT; [2] semi-automated method, maximum attenuation increase on non-registered CTA/NCCT (ΔHUmax); [3] manual method, maximum attenuation on CTA (HUmax); and [4] visual method, residual flow grade. Primary outcome was recanalization with intravenous alteplase on the revised AOL scale (2b/3). Regression models were compared using C-statistic, Akaike (AIC), and Bayesian information criterion (BIC).
Results:
Four hundred eighty patients were included in this analysis. Statistical models using methods 2, 3, and 4 were similar in their ability to discriminate recanalizers from non-recanalizers (C-statistic 0.667, 0.683, and 0.634, respectively); method 3 had the least information loss (AIC = 483.8; BIC = 492.2). A HUmax ≥ 89 measured with method 3 provided optimal sensitivity and specificity in discriminating recanalizers from non-recanalizers [recanalization 55.4% (95%CI 46.2-64.6) when HUmax > 89 vs. 16.8% (95%CI 13.0-20.6) when HUmax ≤ 89]. In sensitivity analyses restricted to patients with co-registered CTA/NCCT (n = 88), methods 1-4 predicted recanalization similarly (C-statistic 0.641, 0.688, 0.640, 0.648, respectively) with Method 2 having the least information loss (AIC 104.8, BIC 109.8).
Conclusion:
Simple methods that measure thrombus permeability are as reliable as complex image processing methods in discriminating recanalizers from non-recanalizers.