Comparison of Post Space Volume Changes Following Fiber Post Removal Using Er,Cr:YSGG Laser Versus Ultrasonic Instrument

Metadata Downloads
Author(s)
Juyeon ChoJie LiuEsraa A. BukhariFengyuan ZhengDo-Gyoon KimDamian J. Lee
Keimyung Author(s)
Cho, Ju Yeon
Department
Dept. of Dentistry (치과학)
Journal Title
J Prosthodont
Issued Date
2022
Volume
31
Issue
3
Keyword
TomographyEr,Cr:YSGG laserultrasonicfiber postpost removal
Abstract
Purpose:
The purpose of this in vitro study was to compare the post space volume changes following removal of glass fiber posts in endodontically treated teeth by using erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser to the conventional ultrasonic method.

Materials and Methods:
Twelve single-root human extracted teeth were cut into 13 mm near cementoenamel junction (CEJ), and then underwent endodontic treatment. The post spaces were prepared to 8 mm in length. Glass fiber posts were inserted with self-curing resin cement. Specimens were randomly assigned to laser or ultrasonic methods for their post removal. Post space volumes were measured using microcomputed tomography (micro-CT) before post cementation and after post removal. Dentin thickness was measured after post removal at coronal, middle, and apical third of the root canal space. Paired t-test and t-test were used to compare space volumes between before post cementation and after post removal, and between laser and ultrasonic groups, respectively.

Results:
Six specimens were tested for each group. The average volume change was 6.499 mm3 in laser and 7.418 mm3 in ultrasonic method. There was not a significant difference between laser and ultrasonic group in respect of post space volume changes (p = 0.71). Both methods showed significant volume increase following post removal (p < 0.05). Significantly less dentin was lost when laser was used for post removal in the coronal portion of the post space (p = 0.002).

Conclusions:
Er,Cr:YSGG laser can be used as effective option, comparable to the conventional ultrasonic method when removing posts in endodontically treated teeth. Laser has the potential to provide conservative post removal.
Keimyung Author(s)(Kor)
조주연
Publisher
School of Medicine (의과대학)
Citation
Juyeon Cho et al. (2022). Comparison of Post Space Volume Changes Following Fiber Post Removal Using Er,Cr:YSGG Laser Versus Ultrasonic Instrument. J Prosthodont, 31(3), 245–251. doi: 10.1111/jopr.13391
Type
Article
ISSN
1532-849X
Source
https://onlinelibrary.wiley.com/doi/10.1111/jopr.13391
DOI
10.1111/jopr.13391
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/44162
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Dentistry (치과학)
공개 및 라이선스
  • 공개 구분공개
  • 엠바고Forever
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.