계명대학교 의학도서관 Repository

Performance of a Novel CT-Derived Fractional Flow Reserve Measurement to Detect Hemodynamically Significant Coronary Stenosis

Metadata Downloads
Author(s)
Si-Hyuck KangSoo-Hyun KimSun-Hwa KimEun Ju ChunWoo-Young ChungChang-Hwan YoonSang-Don ParkChang-Wook NamKi-Hwan KwonJoon-Hyung DohYoung-Sup ByunJang-Whan BaeTae-Jin YounIn-Ho Chae
Keimyung Author(s)
Nam, Chang Wook
Department
Dept. of Internal Medicine (내과학)
Journal Title
J Korean Med Sci
Issued Date
2023
Volume
38
Issue
32
Keyword
Computed TomographyCoronary CT AngiographyFractional Flow ReserveCoronary Artery Disease
Abstract
Background:
Fractional flow reserve (FFR) based on computed tomography (CT) has been shown to better identify ischemia-causing coronary stenosis. However, this current technology requires high computational power, which inhibits its widespread implementation in clinical practice. This prospective, multicenter study aimed at validating the diagnostic performance of a novel simple CT based fractional flow reserve (CT-FFR) calculation method in patients with coronary artery disease.

Methods:
Patients who underwent coronary CT angiography (CCTA) within 90 days and invasive coronary angiography (ICA) were prospectively enrolled. A hemodynamically significant lesion was defined as an FFR ≤ 0.80, and the area under the receiver operating characteristic curve (AUC) was the primary measure. After the planned analysis for the initial algorithm A, we performed another set of exploratory analyses for an improved algorithm B.

Results:
Of 184 patients who agreed to participate in the study, 151 were finally analyzed. Hemodynamically significant lesions were observed in 79 patients (52.3%). The AUC was 0.71 (95% confidence interval [CI], 0.63-0.80) for CCTA, 0.65 (95% CI, 0.56-0.74) for CT-FFR algorithm A (P = 0.866), and 0.78 (95% CI, 0.70-0.86) for algorithm B (P = 0.112). Diagnostic accuracy was 0.63 (0.55-0.71) for CCTA alone, 0.66 (0.58-0.74) for algorithm A, and 0.76 (0.68-0.82) for algorithm B.

Conclusion:
This study suggests the feasibility of automated CT-FFR, which can be performed on-site within several hours. However, the diagnostic performance of the current algorithm does not meet the a priori criteria for superiority. Future research
is required to improve the accuracy.
Keimyung Author(s)(Kor)
남창욱
Publisher
School of Medicine (의과대학)
Type
Article
ISSN
1598-6357
Source
https://jkms.org/DOIx.php?id=10.3346/jkms.2023.38.e254
DOI
10.3346/jkms.2023.38.e254
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/45080
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Internal Medicine (내과학)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.