계명대학교 의학도서관 Repository

Impact of scleral tunnel length on the position of IOLs in flanged intrascleral haptic fixation

Metadata Downloads
Author(s)
Jong Hwa JunJoon-Ho KwakChang-Hyun ParkJiyeon LeeJueun SeongKyu Young ShimNatalie A Afshari
Keimyung Author(s)
Jun, Jong HwaLee, Ji Yeon
Department
Dept. of Ophthalmology (안과학)
Dept. of Internal Medicine (내과학)
Journal Title
J Cataract Refract Surg
Issued Date
2024
Volume
50
Issue
8
Abstract
Purpose:
To investigate the effect of scleral tunnel length on the effective lens position and tilt of the intraocular lens (IOL) in flanged intrascleral haptic fixation (ISHF) using anterior segment optical coherence tomography (AS-OCT).

Setting:
Tertiary institution.

Design:
Retrospective case-control study.

Methods:
This study included 55 and 42 eyes that underwent ISHF with 1.0- and 2.0-mm scleral tunnels, respectively. Twenty-three eyes that underwent sutured fixation were used as a control. The anterior chamber depth (ACD), scleral tunnel length, incident angle of haptic, and tilting of optic were analyzed using AS-OCT.

Results:
The mean postoperative ACD, vertical tilt angle, and spherical equivalent of the 1.0-mm were 5.27 ± 0.39 mm, 6.04 ± 4.87°, and 0.38 ± 1.03 D, respectively. The ACD and vertical tilt angle of the 1.0-mm were larger than those of the others (p<0.001 and p<0.05, respectively), and the postoperative spherical equivalent was more hyperopic (p<0.05). The 2.0-mm exhibited a lower frequency of tilting greater than 7°. The inter-eye difference in ACD between in-the-bag fixation and ISHF of the1.0-mm tunnel was significantly greater than that in the 2.0-mm tunnel (p<0.05). The 1.0 mm tunnel had a significantly larger incident angle and a longer tunnel length (p<0.001, respectively) and showed a greater difference in the tunnel length on both sides (p<0.05).

Conclusion:
A shorter tunnel yielded a more unstable IOL position, greater variation in angle and tunnel length, and longer ACD during ISHF. An exact 2.0-mm tunnel must be created on both sides to achieve a stable and predictable IOL position.
Keimyung Author(s)(Kor)
전종화
이지연
Publisher
School of Medicine (의과대학)
Type
Article
ISSN
1873-4502
Source
https://journals.lww.com/jcrs/abstract/9900/impact_of_scleral_tunnel_length_on_the_position_of.405.aspx
DOI
10.1097/j.jcrs.0000000000001460
URI
https://kumel.medlib.dsmc.or.kr/handle/2015.oak/45881
Appears in Collections:
1. School of Medicine (의과대학) > Dept. of Internal Medicine (내과학)
1. School of Medicine (의과대학) > Dept. of Ophthalmology (안과학)
공개 및 라이선스
  • 공개 구분공개
  • 엠바고Forever
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.