Comparison of Thick Biolimus A9-Eluting Stent and Thin Zotarolimus-Eluting Stent in Multi-Vessel Percutaneous Coronary Intervention
- Author(s)
- Cheol Hyun Lee; Hee Jeong Lee; Tae-Wan Chung; Seonhwa Lee; Jongmin Hwang; In-Cheol Kim
- Keimyung Author(s)
- Lee, Cheol Hyun; Lee, Hee Jeong; Chung, Tae Wan; Lee, Seon hwa; Hwang, Jong Min
- Department
- Dept. of Internal Medicine (내과학)
- Journal Title
- Korean Circ J
- Issued Date
- 2025
- Volume
- 55
- Issue
- 5
- Keyword
- Drug-eluting stent; Percutaneous coronary intervention; Polymer
- Abstract
- Background and Objectives:
There are limited randomized studies on patients undergoing multi-vessel percutaneous coronary intervention (PCI) comparing the outcomes between stent thickness and polymer types. To compare the clinical outcomes of thick biodegradable polymer-based biolimus A9-eluting stents (BESs) and thin durable polymer-based zotarolimus-eluting stents (ZESs) in patients undergoing multi-vessel PCI.
Methods:
A total of 936 patients who underwent multi-vessel coronary artery stenting were randomly assigned to the BES (n=472) or ZES (n=464) groups. The primary endpoint was 2-year major adverse cardiac events (MACEs), a composite of all-cause death, myocardial infarction (MI), and any revascularization at the 2-year follow-up.
Results:
Fifty-two (11.2%) of 472 patients in BES group and 50 (10.9%) of the 464 patients in ZES group met the 2-year primary endpoint of MACE (hazard ratio, 1.00; 90% confidence interval, 0.72, 1.38; p=0.994). All-cause death (BES vs. ZES: 2.8% vs. 2.7%, p=0.758), MI (2.1% vs. 2.6%, p=0.483), and repeat revascularization (6.7% vs. 6.9%, p=0.876) were not significantly different between the 2 groups. Although there was no significant outcome difference in any subgroup analysis, the technical failure rate leading to the use of other stents was higher in BES than in ZES (3.2% vs. 0.9%, p=0.023).
Conclusions:
In patients who underwent multi-vessel PCI, BES and ZES showed comparable 2-year clinical outcomes. However, BES was not established to demonstrate non-inferiority to ZES in terms of the incidence of the primary endpoint at the 2-year. The technical success rate of the index PCI with the assigned stent was higher for thinner ZES.